Danfoss iC2-Micro AC Frequency Inverter for 1.5kW 400V 3 Phase Motor in V/F and Sensorless Vector Control (VVC) to 3.7A.
Output Current Rating: 3.7A
Overload: 150% x 60 seconds.
Size: MA01a - 70mm Wide x 158mm Deep x 150mm High. IP20.
Weight: 1.1kg.
Speed Control Range: 0-200 Hz (VVC+), 0-400 Hz (VxF).
Braking (DBr): Not fitted.
Fixed Keypad with front mounted Potentiometer.
2 x Analogue Inputs, 5 x Digital Inputs, 1 x Analogue Output, 1 Digital Output 1 x Relay Contact set.
Communications: RS485 (twin-wire); FC Protocol, Modbus RTU.
Programmable from a PC using Danfoss MyDrive. (via RS485 input or RJ45 with converter not direct)
Input Current: 5.9A max
Input Voltage: 380-480V (+10% -15%) at 50-60Hz (±5%)
EMC Filters: To IEC/EN 61800-3 2nd Environment (Industrial); 1st Environment with restrictions – C2
Cubicle mount.
Ambient: Rated at 50°C
Ventilation space above and below: 100mm.
Ventilation space at sides: 0mm (drives can be mounted side by side)
Heat Loss at max output: 34W.
Mounting: Via 4 x M4 Fixings at rear on 140.4mm x 55mmcentres
Full part number: IC2-30FA3N0403A7E20F2+ACXX
Type Code: 132L6130
Previous Generation:132F0020; FC-051P1K5T4E20H3 (FC51 has DBr, iC2 does not)