Danfoss FC-202 'Aqua' Series AC Inverter for 22kW in Heavy Duty Mode or 30kW in Fan/Pump Mode. Converts fixed frequency three phase 380-480Vac input to variable frequency three phase 400V to control the speed of a standard AC Induction Motor.
Please check that this is the correct part in item 1.. Special factory order and is non-returnable.
Input Voltage: 380Vac - 480Vac Three Phase ±10% at 50-60Hz ±5%.
Input Current: (380-441Vac) 40A in Heavy Duty Mode. 55A in Fan/Pump Mode.
Input Current: (441-480Vac) 36A in Heavy Duty Mode. 47A in Fan/Pump Mode.
Size B4: 229mm Wide x 242mm Deep x 520mm High. IP20(E20).
Weight: 22.69kg.
Output Current: 380-441VAc: 44A in Heavy Duty Mode. 40A In Fan/Pump Mode.
Output Current: 441-480Vac: 40A in Heavy Duty Mode. 52A in Fan/Pump Mode.
Overload, Heavy Duty: 150% x 60 seconds.
Overload, Fan/Pump Duty: 110% x 60 seconds, 135% x 0.5 seconds.
Speed Control Range: 0-590Hz
Braking: None.
Graphical Keypad, 2 Analogue Inputs, 4 Digital Inputs, 1 Analogue Output, 2 Digital Input/Outputs, 2 Relay Contact sets, DC Bus +/- Terminals, Terminals for RS485 Communications.
FC Protocol, N2 Metasys, FLN Apogee communication protocols built-in as standard.
Programmable from a PC via USB and free Danfoss MCT 10 software.
EMC Compliance: IEC EN55011 First Environment Class C1 (Domestic and Industrial). Can be disabled if required.
Wall mount in clean environment or cubicle mount.
Rated 45°C Ambient.
Ventilation space in front: [not specified], above and below: 200mm, at sides: 0mm.
Efficeincy:98%
Heat Loss at max output: 547W in Heavy Duty Mode. 739W in Fan/Pump Mode.
Mounting via 4 x holes at rear on 200mm x 495mm centres.
Manufacturer part number is 131F6770
Type code is FC-202P30KT4E20H2XGXXXXSXXXXAXBXCXXXXDX.
Download the Danfoss FC202 Manual from the links below:-